尿MCV联合RDW检测对鉴别血尿来源的诊断价值
翘楚医学论文网:专业提供医学论文的写作、修改、翻译、发表
官方网站:https://www.qclunwen.com 服务QQ:55755004
邮箱:55755004@qq.com 咨询电话:18986130979
服务宗旨:原创、专业、诚信、安全可靠
【关键词】 血尿;血液剖析仪;尿红细胞均匀体积;尿红细胞散布宽度
Diagnosis value for identifying source of hematuria by detecting of MCV and RDW in urine
XIAO Hong,XU Bin.Department of Clinical Laboratory,Tianshan Hospital of Traditional Chinese Medicine in Changning District,Shanghai 200051,China
[Abstract] Objective To evaluate the diagnosis value of the source of hematuria through detection of urine MCV and RDW by SYSMEX KX-21 hematoanalyser.Methods The urine samples were collected from 112 patients with 39 patients of G-HMT and 63 patients of NG-HMT.Urine MCV and RDW were analyzed by hematoanalyser.Results The urine MCV patients with G-HMT were smaller than that with NG-HMT.The urine MCV value with more than 73 fl could be diagnosed as NG-HMT;and the MCV value with less than 73 fl as G-HMT.The accuracy of diagnose was high.There was significant difference between the RDW with G-HMT and with NG-HMT(P<0.01).Conclusion There are clinical diagnosis value for identifying the source of hematuria by the detecting of urine MCV and RDW.
[Key words] hematuria;hematoanalyser;urine MCV;urine RDW
血尿是泌尿系统疾病较为常见的临床病症,但怎样鉴别血尿的来源,不断是较为艰难的问题。目前临床较为普遍采用肾病理活检或相差显微镜察看尿红细胞来诊断血尿来源,但是由于肾病理活检是具有创伤性的检查,而显微镜察看尿红细胞形态受个人工作经历、客观要素、尿浸透压、红细胞数量及离心过程等诸多要素影响,其精确性也将遭到一定限制。我们树立的应用SYSMEX KX21血液剖析仪检测尿红细胞体积(MCV)及其散布宽度(RDW),其办法烦琐,结果精确,适用于各级实验室,临床上初步应用有一定的意义。对鉴别诊断血尿来源具有较高的临床诊断价值。
1 材料与办法
1.1 实验对象 112例血尿患者中,肾小球性血尿39例(急性肾炎28例,慢性肾炎11例),非肾小球性血尿63例 (肾输尿管结石15例,前列腺炎7例,慢性肾盂肾炎3例,肾癌9例,膀胱炎3例,膀胱癌8 例,尿路感染8例,前列腺癌10例)。
1.2 仪器及试剂 日本东亚公司SYSMEX KX21血液剖析仪及剖析仪原装配套试剂。
1.3 办法 运用SYSMEX KX21血液剖析仪对血样及尿样停止检测,详细操作如下:(1)取患者EDTA抗凝血直接停止血常规检测,提取MCV与RDW值。(2)取患者新颖(2 h以内)中段尿10 ml于锥形刻度管中,以1 500 r/min离心5 min,弃去上清液,汲取红细胞层10 μl加0.25 ml原装稀释液,用预先稀释形式检测尿MCV与RDW。
1.4 统计学剖析 采用Microsoft Excel 2000软件停止数据统计剖析。浓度用均数±规范数(x±s)表示、显著性检验用成组t检验。
2 结果
112例血尿患者用SYSMEX KX-21全自动血液剖析仪测定尿MCV,39例肾小球性血尿患者尿MCV为(69.40±3.63) fl,62例非肾小球性血尿患者尿MCV为(93.51±5.00) fl,P<0.01,两者差别存在显著性,见表1。表1 SYSMEX KX-21测定尿MCV结果
一切实验对象均用SYSMEX KX-21全自动血液剖析仪测定血与尿MCV,39例肾小球性血尿患者血MCV为(90.43±4.72)fl,尿MCV为(69.40±3.63) fl,两者存在显著差别。63例非肾小球性血尿患者血MCV为(91.92±2.90) fl,尿MCV为(93.63±5.00) fl,P>0.05,两者差别无显著性,见表2。表2 SYSMEX KX-21测定血与尿MCV比拟
一切实验对象均用SYSMEX KX-21全自动血液剖析仪测定尿RDW-SD,39例肾小球性血尿患者尿RDW-SD为52.11±4.106,63例非肾小球性血尿患者RDW-SD为42.23±4.57,两者存在显著差别。见表3。表3 比拟结果
3 讨论
血尿是泌尿系统疾病常见的病症,肾小球性血尿红细胞经过有病变的肾小球基膜时遭到机械性切割、挤压,同时遭到肾小管内不同pH、浸透压和代谢产物的影响,发作外形及大小多样化变化,结果使其体积变小,大小不匀;非肾小球性血尿,主要指肾小球以下部位和泌尿通路上的出血,红细胞没有经过肾小球基膜,其体积、形态无明显变化[1] 。据国外文献Shichiri等[2]研讨结果标明非肾小球性血尿与肾小球性血尿红细胞体积散布曲线存在很大区别,其中非肾小球性血尿的该曲线正常,而肾小球性血尿的该曲线的散布峰在较小的细胞体积内。本文对2组血尿患者停止尿MCV与RDW检测,同时对两组患者停止本身血与尿的MCV比对实验,发现肾小球性血尿患者尿MCV明显小于非肾小球血尿患者,肾小球性血尿患者血MCV与尿MCV相差较大两者有显著差别,而非肾小球血尿患者血MCV与尿MCV相差较小两者无显著差别。肾小球性血尿患者RDW明显大于非肾小球血尿患者,肾小球性血尿患者尿MCV明显小于非肾小球性血尿患者,两者存在较大差别。肾小球性患者尿RDW明显大于非肾小球性血尿,两者存在较大差别。辅佐临床诊治,其办法烦琐,技术请求不高,结果牢靠,易于临床实验室展开。
【参考文献】
1 王海燕.肾脏病学,第2版.北京:人民卫生出版社,1996,282-287.
2 Shichiri M,Oowada A,Nishio Y,et al.Ues of an autoanalyser to examine urinary red-cell morphology in the diagnosis of glomerular haematuria.Lancet,1986,2:781-782.